More than 40 years of experience in the field of HVAC

055 20 325 30

Ordering or Information

E-mail

Ordering or Information

Ordering or Information

Ordering or Information

What are calibrated sensors?

Calibrated sensors deliver high measurement accuracy because manufacturers individually inspect, test and document each sensor against a reference standard. During the calibration process they compare the sensor with an accurate reference sensor at multiple measurement points. They record the deviations and correct them where possible so that the sensor remains within a guaranteed tolerance. As a result the sensor provides a reliable, reproducible and traceable measurement.

The main purpose of calibrated sensors is to provide a measurement as close as possible to the actual physical value. Standard sensors often offer sufficient accuracy for general HVAC applications, but calibrated sensors are indispensable in installations where even small deviations are undesirable or have direct consequences for energy consumption, reporting obligations or process quality.

Suppliers usually provide calibrated sensors with a test report or certificate. This document states exactly under which conditions the sensor was tested, which deviations were measured and which accuracy class applies. This ensures these sensors meet the requirements of standards, audits and quality guidelines.

Applications of calibrated sensors

1. Energy reporting and building management systems

When temperature or humidity measurements are logged and used for energy reporting, benchmarking or performance analyses, a correct absolute value is important. Calibrated sensors ensure that the measured values are reliable enough for analysis and documentation.

2. Heating and cooling installations

In systems with billing or allocation based on energy consumption (such as district heating networks, commercial buildings and industrial installations) calibrated sensors are often necessary. A small deviation in temperature or flow can result in a large error in the energy calculation.

3. Rooms with standards or strict climate conditions

In rooms such as data centers, museums, archive rooms, laboratories or production sites with climate standards, calibration is essential. Here the sensor must meet strict margins to ensure the desired indoor climate and protect critical processes.

4. Air handling and process air

For accurate control of humidity, temperature or pressure in air handling units it is important that the sensor knows the true absolute value. A calibrated sensor provides greater certainty when setting processes such as drying, cooling, heating and ventilating.

5. Industry and process automation

In production processes where temperature, pressure or humidity directly affect product quality or safety, calibration is mandatory or strongly recommended. Traceability is an important part of the quality policy.

Where are calibrated sensors used?

Calibrated sensors are widely used in sectors where measurement accuracy is essential. Think of:

  • commercial buildings
  • laboratories
  • pharmaceutical industry
  • food processing
  • data centers
  • GBS/BMS systems
  • energy management
  • climate and process installations
  • museums and archives

Difference with paired sensors

Calibrated sensors focus on absolute accuracy, that is how correctly the sensor measures the actual value. Paired sensors focus on mutual similarity so that two or more sensors match each other perfectly for differential measurements such as delta-T.

Do you have questions about this article or the products of Betec Controls BV? Then contact us! Or you can also use the chat function!

Featured news

Safety actuator: why choose a safety function?

A safety actuator automatically moves a damper to a predefined safe position in the event of a fault. This type of actuator is also known as a fail-safe actuator, safety...
Read more >
CO2_VOC_PM

How do you measure air quality? CO₂, VOC and PM sensors explained

Good air quality is important for comfort, concentration, and a healthy indoor climate. That is why in more and more buildings Sensoren are used to monitor air quality. But how...
Read more >
Produal Solutions

Produal Solutions

INSPIRATION & SOLUTIONS Produal solutions for every building environment From hotels and shopping malls to hospitals and museums.  Discover how Produal’s measurement and control technology creates a more comfortable, energy-efficient,...
Read more >
Comfort without noticing

HVAC control technology for hotels

Produal hotel solutions HVAC-regeltechniek voor hotels Together, we build sustainable performance in modern hotel environments Hotels are successful when rooms are comfortable, quiet and easy for guests to operate, while...
Read more >
Shopping Centre Solutions

HVAC control technology for shopping centres with Produal

HVAC control technology for shopping centres with Produal A comfortable indoor climate where visitors enjoy spending time and retail can perform. A comfortable indoor climate where visitors enjoy spending time...
Read more >

Accurate climate measurements for buildings

Accuratemeasurementsforoptimalcomfort Maximale energie-efficiëntie en comfort Produal room transmitters with patented Produal ProTemp™ Technology ensure accurate measurements, reliable control and demonstrable quality. Produal ProTemp™ Technology ensures that Produal room transmitters accurately...
Read more >
REFERENCES

Produal references

REFERENCES Produal reference projects for building automation More than 30 years of expertise in buildings around the world Produal’s expertise can be found in tens of thousands of buildings around...
Read more >
Calectro CR controllers and transmitters for HVAC

Calectro CR: controllers and transmitters for indoor climate control

The Calectro CR series is a new product family for measuring and controlling the indoor climate. The series consists of CRC controllers and CRT transmitters for applications involving CO2, temperature...
Read more >
Operation and selection of control valves

Operation and selection of control valves

Selecting a control valve starts with a good understanding of the installation. The valve Controls the flow rate of water through, for example, a heat exchanger, heating coil or cooling...
Read more >
LS02WK01

LS02+ leakage sensor and WK01+ condensation switch: when should you choose which one?

The LS02+ leakage sensor and WK01+ condensation switch each have a different function within HVAC and climate installations. The LS02+ detects the unwanted presence of water. The WK01+ specifically signals...
Read more >
ATEX temperature classes

What are ATEX zones and which T-classes are there?

ATEX zones relate to environments where an explosion hazard can arise due to gas or dust. ATEX is derived from the French term Atmosphères Explosibles. The European ATEX directives relate...
Read more >

Replacing HVAC components: what to consider during retrofit?

Replacing an existing HVAC component with a new type requires more than just the brand and type number. The technical properties of the existing component determine which replacement is suitable....
Read more >

Contact Form

Do you have any questions or would you like more information? Please fill out our contact form and we will ensure that you receive a response within one business day. Our team is ready to assist you promptly with all your inquiries.