Produal DPT Differential Pressure Sensor – Features and Applications

The DPT series differential pressure sensors from Produal (formerly HK Instruments) are specifically designed for accurate measurements in air and climate control systems (HVAC), such as building management systems, industrial ventilation systems, and cleanrooms, where reliable pressure measurements are essential. In addition, DPT sensors stand out due to their flexibility and ease of use.

How does the DPT sensor work?

The DPT differential pressure sensor uses modern MEMS technology (Micro-Electro-Mechanical Systems), ensuring high accuracy and stability both in the short and long term.
The DPT (Differential Pressure Transmitter) measures the pressure difference between two pressure points, for example before and after a filter or fan. Depending on the model, the measured pressure difference is either converted into an electrical signal (such as 0–10 V or 4–20 mA) or communicated digitally via Modbus to the building management system (BMS).

Key features of the DPT series

  • 8 selectable ranges in a single device
  • High accuracy, approx. 1% of the measured value
  • Automatic zero point correction (AZ) and display depending on the version
  • Multiple output signals: analog (0–10 V, 4–20 mA) or digital (Modbus)

Applications

  • Monitoring of airflow and fans in ventilation systems
  • Monitoring and detection of filter contamination
  • Monitoring of overpressure and underpressure in cleanrooms
  • Optimization of energy consumption and comfort in buildings

Advantages of the DPT series

  • Reliable and stable measurements
  • Reduced maintenance thanks to smart technology
  • Flexible application due to adjustable parameters
  • Easy integration into modern building management systems

 

Do you have questions about these products? Please contact us. Or feel free to use the chat function! 🚀

Featured news

Safety actuator: why choose a safety function?

A safety actuator automatically moves a damper to a predefined safe position in the event of a fault. This type of actuator is also known as a fail-safe actuator, safety...
Read more >
CO2_VOC_PM

How do you measure air quality? CO₂, VOC and PM sensors explained

Good air quality is important for comfort, concentration, and a healthy indoor climate. That is why in more and more buildings Sensoren are used to monitor air quality. But how...
Read more >
Produal Solutions

Produal Solutions

INSPIRATION & SOLUTIONS Produal solutions for every building environment From hotels and shopping malls to hospitals and museums.  Discover how Produal’s measurement and control technology creates a more comfortable, energy-efficient,...
Read more >
Comfort without noticing

HVAC control technology for hotels

Produal hotel solutions HVAC-regeltechniek voor hotels Together, we build sustainable performance in modern hotel environments Hotels are successful when rooms are comfortable, quiet and easy for guests to operate, while...
Read more >
Shopping Centre Solutions

HVAC control technology for shopping centres with Produal

HVAC control technology for shopping centres with Produal A comfortable indoor climate where visitors enjoy spending time and retail can perform. A comfortable indoor climate where visitors enjoy spending time...
Read more >

Accurate climate measurements for buildings

Accuratemeasurementsforoptimalcomfort Maximale energie-efficiëntie en comfort Produal room transmitters with patented Produal ProTemp™ Technology ensure accurate measurements, reliable control and demonstrable quality. Produal ProTemp™ Technology ensures that Produal room transmitters accurately...
Read more >
REFERENCES

Produal references

REFERENCES Produal reference projects for building automation More than 30 years of expertise in buildings around the world Produal’s expertise can be found in tens of thousands of buildings around...
Read more >
Calectro CR controllers and transmitters for HVAC

Calectro CR: controllers and transmitters for indoor climate control

The Calectro CR series is a new product family for measuring and controlling the indoor climate. The series consists of CRC controllers and CRT transmitters for applications involving CO2, temperature...
Read more >
Operation and selection of control valves

Operation and selection of control valves

Selecting a control valve starts with a good understanding of the installation. The valve Controls the flow rate of water through, for example, a heat exchanger, heating coil or cooling...
Read more >
LS02WK01

LS02+ leakage sensor and WK01+ condensation switch: when should you choose which one?

The LS02+ leakage sensor and WK01+ condensation switch each have a different function within HVAC and climate installations. The LS02+ detects the unwanted presence of water. The WK01+ specifically signals...
Read more >
ATEX temperature classes

What are ATEX zones and which T-classes are there?

ATEX zones relate to environments where an explosion hazard can arise due to gas or dust. ATEX is derived from the French term Atmosphères Explosibles. The European ATEX directives relate...
Read more >

Replacing HVAC components: what to consider during retrofit?

Replacing an existing HVAC component with a new type requires more than just the brand and type number. The technical properties of the existing component determine which replacement is suitable....
Read more >

Contact Form

Do you have any questions or would you like more information? Please fill out our contact form and we will ensure that you receive a response within one business day. Our team is ready to assist you promptly with all your inquiries.