Description
CO2, temperature, controller
aSENSE VAV Display
_x000D_ aSENSE VAV is a standalone controller with built-in sensors for temperature, humidity, and carbon dioxide. The unit measures both the CO₂ concentration and the temperature in the ambient air and converts the data into analog and digital output signals, which are used to control the air supply on demand. An additional cooling compressor for dehumidification can also be controlled. aSENSE VAV is intended for installation in the climate zone or in a ventilation duct._x000D_ APPLICATIONS_x000D_ A common and extensive application for aSENSE VAV is controlling ventilation where people are present. The Sensor is flexible and designed for many different ventilation strategies. It is an important component for energy-efficient, healthy climate control of spaces with varying occupancy, such as daycare centers, sports centers, etc. In museums and libraries, etc., the ventilation control based on temperature and carbon dioxide measurements can be combined with air management. To prevent condensation problems, it is often necessary to measure humidity in air conditioning and other cooling applications. This Sensor is a basic component that can be used in many different ventilation applications, used in industrial/agricultural process controls. Alternative control outputs
_x000D_
- Contributes to lower energy costs when used in demand-driven ventilation
_x000D_
- Internal automatic self-diagnostics
_x000D_
- Maintenance-free
_x000D_
- Available with various measurement ranges and different enclosure options
_x000D_
- Serial communication port for connection to a PC or a GSM module and local network
_x000D_
_x000D_
Technical specifications
_x000D_
_x000D_
_x000D_
_x000D_
Product number
_x000D_
045- 8-0001
_x000D_
_x000D_
_x000D_
Measurement range CO2
_x000D_
0 – 2,000 ppm
_x000D_
_x000D_
_x000D_
Accuracy
_x000D_
±30 ppm ±3% of the reading value
_x000D_
_x000D_
_x000D_
Dimensions
_x000D_ < td align=”left” valign=”top”>120 mm x 82 mm x 30 mm
_x000D_
_x000D_
_x000D_
Measurement range temperature< /td>_x000D_
0 to +50°C
_x000D_
_x000D_
_x000D_
Measurement range humidity
_x000D_
0 to 95% RH (non-condensing)
_x000D_
_x000D_
_x000D_
Power supply
_x000D_
24 VAC/VDC ±20%, 50-60 Hz (input half-wave rectifier)
_x000D_
_x000D_
_x000D_
Power consumption
_x000D_
< 3 Watts average
_x000D_
_x000D_
_x000D_
Communication
_x000D_
Uart (Modbus)
_x000D_
_x000D_
_x000D_
Outputs
_x000D_
_x000D_
_x000D_
_x000D_
OUT1 linear output
_x000D_
0/2 to 10 V DC or 0/4-20mA (CO2)
_x000D_
_x000D_
_x000D_
OUT2 linear output
_x000D_
0/2 to 10 V DC or 0/4-20mA (°C)
_x000D_ </ tr>_x000D_
_x000D_