UG-3-A4O

Article number: UG-3-A4O

Optical duct smoke detector with automatic sensitivity adjustment, service alarm and built-in control unit, 24V | UG-3-A40

Order or information?
View quote

Why choose Betec Controls?

Description

Duct Smoke DETECTOR Uniguard UG-3-A40

Optical duct smoke DETECTOR with automatic sensitivity adjustment, service alarm and built-in control unit, 24V | UG-3-A40

Description UG-3-A4O

The Uniguard is developed to detect smoke in ventilation ducts. It consists of a smoke DETECTOR with relay outputs mounted in an adapter system. The tube as well as the housing are specifically designed for optimal airflow through the smoke DETECTOR.
The system meets all requirements for proper fire detection with airflow speeds from 0.2 m/s to 20 m/s.
A venturi tube with auxiliary fan can be used to detect smoke in situations where ventilation is switched off and therefore there is limited airflow in the duct.
Uniguard has a built-in control unit to control fire dampers and fans, or to activate acoustic and/or optical alarms etc.
Since the duct smoke DETECTOR is equipped with a bayonet lock, it is therefore easy to replace.
UG-3-A4O has an intelligent monitoring circuit that continuously checks and adjusts the sensitivity for optimal functionality throughout the entire service life of the DETECTOR. When the duct smoke DETECTOR can no longer compensate for environmental influences, a service alarm is triggered. This indicates that it is time to replace or clean the DETECTOR.
Uniguard Superflow has 4 pre-mounted Clickseal-type IP67 approved cable entries with automatic strain relief for cable diameters 4 – 11 mm.

Installation

The venturi tube is made of aluminum and can be easily shortened. Afterwards it can fit the diameter of the duct. Hole-Ø is 38 mm. For insulated/round ducts with mounting bracket, Ø is 51 mm.

Once the installation is complete, it is necessary to test the duct smoke DETECTOR. The test can be performed with test spray SOLO A5 (from Calectro). A short spray through the test hole in the cover should be sufficient. Replace the plastic plug after the test.

NB: If installation takes place outdoors or in cold attics etc., the DETECTOR must be insulated from ambient air. For example, with our weatherproof housing UG-COVER. In such cases it is advisable to mark this with a sign “HIDDEN DETECTOR”.

Do you have questions about this product? Please contact us! This can be by phone, email, or also conveniently via the chat function.

Additional information

Eigenschappen

<li>Built-in control unit (Stand Alone), 24V</li>
<li>2 alarm relays</li>
<li>1 service alarm relay</li>
<li>Automatic sensitivity adjustment: fewer false alarms and longer lifespan</li>
<li>Quick and simple installation</li>
<li>Flow indicator with high sensitivity</li>
<li>New venturi pipe shape provides maximum venturi effect</li>
<li>Foolproof pipe mounting, cannot be installed incorrectly</li>
<li>Complete with pre-assembled cable entries</li>
<li>Test hole in cover</li>
<li>Patented</li>

Protection class

IP67

Type of measurement

Smoke

Supply voltage AC/DC

AC/DC 24V

Brand

Calectro

Calectro's activities are based on components such as sensors. The company was founded in 1969 and is based in Gothenburg, Sweden. Calectro's best-known product is the red Uniguard® single-pipe smoke detector for ventilation ducts, which is used by virtually every major company in building automation across Europe. It is a customer-oriented company that offers many possibilities through a wide range of products. They sell both ready-to-use units and offer OEM solutions to always be able to deliver what our customers request. The range mainly consists of various types of smoke detectors, which are almost always available from our stock.Technical documentation can be found with the respective product. If you still have questions, call us at (0578) 577 179, we will be happy to assist you!

Related products

UG-3-A40 channel smoke detector

UG-3-A50

Optical duct smoke detector with automatic sensitivity adjustment,...
vr06

VR-2.8M

Venturi pipe 2.8 meters for Uniguard Superflow, UG-3/4...
UG-7-A60 channel smoke detector

UG-7-A6O

Optical smoke detector for duct installation, for the...
vr06

VR-1.5M

Venturi pipe 1.5 meters for Uniguard Superflow, UG-3/4...
vr06

VR-0.6M

Venturi pipe 0.6 meter for Uniguard Superflow, UG-3/4...
UG-5-AFR duct smoke detector

UG-5-AFR-230V

Optical duct smoke detector with automatic sensitivity adjustment,...

UG-7

Single-pipe venturi pipe system Uniguard Superflow for OEM....
Do you have a question aboutUG-3-A4O?
Our product experts are ready to answer all your questions
055 203 25 30

Available from 09:00 - 12:30 and from 13:00 - 17:00

info@beteccontrols.nl

Response within 1 business day

Contact Form

Do you have any questions or would you like more information? Please fill out our contact form and we will ensure that you receive a response within one business day. Our team is ready to assist you promptly with all your inquiries.